Watch the travel time error caused  by the gravity effect, and the factory calibration of the movement, the  individual wearing habits, the ambient temperature changes, movement of  material, table oil quality will increase or decrease the objective  conditions gravity on the accuracy of travel time effects. The world is  not entirely accurate mechanical watches, mechanical watches with quartz  accuracy can not be compared. Some friends say that their mechanical  watches in a period of time can quite true or error is small, which is  actually a day to wear different directions cancel each other under the  positive and negative results. The quality of a watch to judge should  look at the stability of travel time it should not be excessive pursuit  of zero error. Such as a month on average almost five seconds off the  table every day, that it is error of 2 points a month and a half, many  of my friends think that the general accuracy of this table, in the eyes  of experts, it is indeed a good stability of the table , compared to  those in the normal case wear tomorrow, but today's fast-slow 2 seconds 3  seconds better than the quality of the table.
What is normal wear? About the same  time you get up every morning wearing a watch, the unit normal work day  off from work to home to the table, according to your usual habits of  the table on the table in the box, repeat the same steps the next day  called normal wear. If you brought today, tomorrow, without a break, it  is not normal wear, in which case the error table will change because of  wear conditions change, but can not say that it changes the stability  of the movement, because the stability of comparison made in the same  circumstances, I believe this point the Swiss chronometer testing to  understand the way friends should be very clear. I consulted a senior  repair master table, when he thought to go unstable if the case, for  example, under normal wear conditions, watch a few seconds there  tomorrow, but today's fast-slow case of a few seconds, the movement of  oil may occur changes need to wash up or watch the oil by a magnetic. He  also said that whether or chronometer tourbillon is a margin of error,  they are more than ordinary table advantage is that the conditions laid  down in the normal wear when the stability, the basic error of the  difference a day can be less than 1 second, excessive pursuit of  mechanical stability of the error is not a lot of attention to the error  table fans, should not be advocated. Finally, under the watch movement,  said teething problems, I've always thought that when the new tables go  quickly is good, with a period of time the watch had a run-in period  will be more accurate, but in fact this is a misunderstanding. Watch is  not a car, precision machinery, spare parts are not allowed any  glitches, and did not need running. Create a new watch to wear away  after a period of time-varying accurate because the wearer has formed a  habit of wearing, the objective of wear produced a relatively stable  environment, the watch worn in different directions under the error of  plus or minus offset and bring more to wear quasi-feel it. 

 
  
 



 
No comments:
Post a Comment